- Plug power cord into UAP.
- Plug ethernet cable into UAP.
- Plug Gray Serial (null-modem) cable into UAP.
- Plug other end of gray cable into PC.
- Select (2) Data Stream
- Start “Terminal” session with these COM settings:
- Bits per second: 9600
- Data bits: 8
- Parity: None
- Stop Bits: 1
- Flow control:
None
- After the settings are configured press <ENTER>
- Default username is “intermec”
- Default password is “intermec”
- Highlight TCP/IP Settings, press <ENTER>.
- Enter IP address.
- Enter subnet mask.
- Enter IP Router (Gateway), if necessary.
- DHCP Mode should be set to “Use DHCP if Address is Zero”.
- Press <ESC>to return to Main Menu.
- Highlight IEEE 802.11b Radio, press <ENTER> .
- Set SSID to something besides the default of “Intermec”. Note this value.
- If using multiple UAPs, set unique Frequency. Overlapping UAPs should not be set on the same frequency.
- Highlight Configure Security Settings for this Radio and press <ENTER>.
- Highlight Enable Static WEP Encryption; set the WEP Transmit Key to 1; enter a unique WEP Key 1. This value must be 5, 13, 16 digits in length. Note
this value.
- Press <ESC> until you to return to Main Menu.
- Save Configuration.
- Reboot.
|